For rim panic devices the strike plate is mounted on the door frame a mullion for double doors or the inactive door for double doors without a center mullion.
Panic device for double doors.
Understanding code requirements for panic hardware.
It is usually only installed on doors that are required by law to have panic hardware.
Long and comes in an aluminum finish.
A rim panic device is surface mounted on the door with the latch projecting from the panic device rather than the door edge.
The global door controls th1100edtbarf fire rated touch panic the global door controls th1100edtbarf fire rated touch panic bar is 36 in.
Trusted brands including von duprin falcon precision dormakaba sargent and yale.
The 2 devices are most commonly used in.
7000 series architectural exit devices.
Doors serving electrical rooms with equipment rated 1 200 amperes or more and over 6 feet wide that contain overcurrent devices switching devices or control devices with exit access.
Alarmed exit hardware featuring a rugged construction designed for functioning reliability sargent alarmed exit hardware uses both audio and visual indicators to signal and.
The 2 devices are most commonly used in.
Panic hardware used on balanced doors must be touchpad type and the touchpad must not extend more than half the width of the door measured from the latch side.
The active door of the pair is typically prepped for a locking device such as a lockset or exit device.
With specific high traffic or high hazard occupancy such as educational or assembly facilities with more than.
Exit devices or push pull hardware is required to make both doors active.
In ul cul fire listed functions and a range of aesthetics and finishes yale s exit devices are ready to withstand the rigors of everyday use and abuse.
Panic hardware is installed and used on doors as an exit device.
The inactive side is then secured by a vertical rod exit device which latches at the top of the door frame and into the threshold.
The exit device is suitable for all doors aluminum hollow metal or wood where there is no projection on the face.
When a set of double doors has both a vertical rod exit device and a rim exit device the rim exit device strike is mounted to the normally inactive side of the double doors.
The inactive door or fixed door is prepped for flush bolts top and bottom and includes an astragal which covers or closes the gap between the edges of the doors.
Single double door applications.
International building code ibc only requires this type of hardware on buildings.
Offered with four available functions the heavy duty 20 series features a rugged design of angled covers and a tapered push rail that fully extends across the door.